Please use this identifier to cite or link to this item: https://www.um.edu.mt/library/oar/handle/123456789/102964
Title: Edentulismo afeta hemodinâmica mandibular em indivíduos idosos : estudo in vivo
Other Titles: Edentulism affects mandibular hemodynamics in elderly
Authors: Baladi, Marina Gazzano
Arita, Emiko Saito
Aoki, Eduardo Massaharu
Cortes, Arthur R. G.
Salgado, Daniela Miranda Richarte de Andrade
Costa, Claudio
Freitas, Claudio Fróes de
Keywords: Mandibular canal -- Ultrasonic imaging -- Evaluation
Blood flow -- Measurement
Laser Doppler blood flowmetry
Edentulous mouth -- Risk factors
Hemodynamics
Issue Date: 2016
Publisher: Faculdade de Odontologia de Lins
Citation: Baladi, M. G., Arita, E. S., Aoki, E. M., Cortes, A. R. G., Salgado, D. M. R. D. A., Costa, C., & Freitas, C. F. D. (2016). Edentulismo afeta hemodinâmica mandibular em indivíduos idosos: estudo in vivo [Edentulism affects mandibular hemodynamics in elderly]. Revista da Faculdade de Odontologia de Lins, 26(1), 5-10.
Abstract: Introdução: A ultrassonografia apresenta um papel importante na caracterização da hemodinâmica mandibular e fornece a possibilidade de análise de alterações na vascularização relacionadas ao edentulismo. Objetivo: Analisar a hemodinâmica de artérias mandibulares responsáveis pela nutrição do tecido ósseo por meio da Ultrassonografia modo B e Doppler em pacientes idosos dentados e edêntulos. Material e Método: 60 exames de ultrassonografia das artérias Alveolar Inferior (AAI) e Mentual (AM) foram avaliados em dois grupos de pacientes: G1 – 15 pacientes idosos edêntulos e G2 – 15 pacientes dentados, ambos com idade média cronológica acima de 60 anos. As variáveis analisadas foram: Índice de Resistência Vascular (IRV), Índice de Diâmetro (ID), Velocidade de Pico Sistólico (VPS) e Hemodinâmica. O teste estatístico utilizado foi o Teste t não pareado a um nível de significância de 5%. Resultados: Foi demonstrado que os valores da hemodinâmica de AAI e AM, lados esquerdo e direito, foram menores no G1 do que no G2. Nos pacientes edêntulos com atrofia mandibular, o fluxo sanguíneo da AM foi menor quando comparado com o da AAI. Conclusão: Nos pacientes edêntulos, a atrofia mandibular modifica o fluxo sanguíneo nas artérias mandibulares.
Introduction: The ultrasonography has an important role in the characterization of hemodynamics and provides the possibility to analyze changes in vascularization. Objective: To analyze the hemodynamic in mandibular arteries responsible for the nutrition of bone tissue through ultrasound B mode and Doppler. Material and Methods: The results of 60 ultrasound exams of the Arteries Inferior Alveolar (AIA) and Mentual (MA) were evaluated in two groups of patients: G1 – 15 edentulous elderly patients and G2 – 15 patients both with average chronological age above 60 years old. The variables analyzed were: Vascular Resistance Index (VRI), Diameter Index (DI), Peak Systolic Velocity (PSV) and Hemodynamics. The statistical test used was the T test unpaired at 5% significance level. Results: It has been shown that the hemodynamic values of AIA and MA, left and right sides were lower in G1 compared to G2. In edentulous patients with mandibular atrophy, blood flow of MA was lower when compared to that of AIA. Conclusion: In edentulous patients, the mandibular atrophy modifies the blood flow in mandibular arteries.
URI: https://www.um.edu.mt/library/oar/handle/123456789/102964
Appears in Collections:Scholarly Works - FacDenDS

Files in This Item:
File Description SizeFormat 
Edentulismo afeta hemodinamica mandibular em individuos idosos estudo in vivo 2016.pdf
  Restricted Access
602.26 kBAdobe PDFView/Open Request a copy


Items in OAR@UM are protected by copyright, with all rights reserved, unless otherwise indicated.