Please use this identifier to cite or link to this item: https://www.um.edu.mt/library/oar/handle/123456789/16668
Full metadata record
DC FieldValueLanguage
dc.contributor.authorMicallef, Daniel-
dc.contributor.authorBuhagiar, Vincent-
dc.contributor.authorBorg, Simon Paul-
dc.date.accessioned2017-02-21T11:05:43Z-
dc.date.available2017-02-21T11:05:43Z-
dc.date.issued2016-
dc.identifier.citationMicallef, D., Buhagiar, V., & Borg, S. P. (2016). Cross-ventilation of a room in a courtyard building. Energy and Buildings, 133, 658-669.en_GB
dc.identifier.issn03787788-
dc.identifier.urihttps://www.um.edu.mt/library/oar//handle/123456789/16668-
dc.description.abstractThe influence of courtyard height on the cross-ventilation of a room abating a courtyard building isaddressed in this work. While the cross-ventilation performance of isolated buildings has been thor-oughly documented in the literature, the phenomenon is still not tackled in the context of a courtyardbuilding, both in isolated as well as urban conditions. This has important implications on the design ofsuch buildings (both new and retrofitted). A numerical approach using Computational Fluid Dynamics(CFD) is used to address these challenges. A courtyard model is first validated in 2D and 3D, using variousturbulence models with existing data in order to determine whether a 3D approach is necessary for thisstudy. Three generic buildings having different heights with a room located on the leeward side are thentested. This is performed for an isolated building and an urban scenario. Results show that there is anincrease in the ventilation flow rate with increasing building height. Moreover, this flow is directed fromoutside the building and into the courtyard. This result has been confirmed for all scenarios tested. Theconsideration of rooms located in positions other than the leeward side of the building is left for futureconsideration.en_GB
dc.language.isoenen_GB
dc.publisherElsevier Ltd.en_GB
dc.rightsinfo:eu-repo/semantics/restrictedAccessen_GB
dc.subjectBuildingsen_GB
dc.subjectBuildings -- Aerodynamicsen_GB
dc.subjectNatural ventilationen_GB
dc.subjectCourtyardsen_GB
dc.subjectComputational fluid dynamicsen_GB
dc.titleCross-ventilation of a room in a courtyard buildingen_GB
dc.typearticleen_GB
dc.rights.holderThe copyright of this work belongs to the author(s)/publisher. The rights of this work are as defined by the appropriate Copyright Legislation or as modified by any successive legislation. Users may access this work and can make use of the information contained in accordance with the Copyright Legislation provided that the author must be properly acknowledged. Further distribution or reproduction in any format is prohibited without the prior permission of the copyright holderen_GB
dc.description.reviewedpeer-revieweden_GB
dc.identifier.doihttp://dx.doi.org/10.1016/j.enbuild.2016.09.053-
Appears in Collections:Scholarly Works - FacBenED

Files in This Item:
File Description SizeFormat 
Cross-ventilation of a Room in a Courtyard Building.pdf
  Restricted Access
2.05 MBAdobe PDFView/Open Request a copy


Items in OAR@UM are protected by copyright, with all rights reserved, unless otherwise indicated.