dc.description.abstract | The influence of courtyard height on the cross-ventilation of a room abating a courtyard building isaddressed in this work. While the cross-ventilation performance of isolated buildings has been thor-oughly documented in the literature, the phenomenon is still not tackled in the context of a courtyardbuilding, both in isolated as well as urban conditions. This has important implications on the design ofsuch buildings (both new and retrofitted). A numerical approach using Computational Fluid Dynamics(CFD) is used to address these challenges. A courtyard model is first validated in 2D and 3D, using variousturbulence models with existing data in order to determine whether a 3D approach is necessary for thisstudy. Three generic buildings having different heights with a room located on the leeward side are thentested. This is performed for an isolated building and an urban scenario. Results show that there is anincrease in the ventilation flow rate with increasing building height. Moreover, this flow is directed fromoutside the building and into the courtyard. This result has been confirmed for all scenarios tested. Theconsideration of rooms located in positions other than the leeward side of the building is left for futureconsideration. | en_GB |
dc.language.iso | en | en_GB |
dc.publisher | Elsevier Ltd. | en_GB |
dc.rights | info:eu-repo/semantics/restrictedAccess | en_GB |
dc.subject | Buildings | en_GB |
dc.subject | Buildings -- Aerodynamics | en_GB |
dc.subject | Natural ventilation | en_GB |
dc.subject | Courtyards | en_GB |
dc.subject | Computational fluid dynamics | en_GB |
dc.title | Cross-ventilation of a room in a courtyard building | en_GB |
dc.type | article | en_GB |
dc.rights.holder | The copyright of this work belongs to the author(s)/publisher. The rights of this work are as defined by the appropriate Copyright Legislation or as modified by any successive legislation. Users may access this work and can make use of the information contained in accordance with the Copyright Legislation provided that the author must be properly acknowledged. Further distribution or reproduction in any format is prohibited without the prior permission of the copyright holder | en_GB |
dc.description.reviewed | peer-reviewed | en_GB |
dc.identifier.doi | http://dx.doi.org/10.1016/j.enbuild.2016.09.053 | - |
Appears in Collections: | Scholarly Works - FacBenED |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
Cross-ventilation of a Room in a Courtyard Building.pdf Restricted Access | 2.05 MB | Adobe PDF | View/Open Request a copy |
Items in OAR@UM are protected by copyright, with all rights reserved, unless otherwise indicated.