dc.identifier.citationFormosa, D., Hunger, R., Spiteri, A., Dong, H., Sinagra, E., & Buhagiar, J. (2012). Corrosion behaviour of carbon S-phase created on Ni-free biomedical stainless steel. Surface and Coatings Technology, 206(16), 3479-3487.en_GB
dc.identifier.urihttps://www.um.edu.mt/library/oar//handle/123456789/18328-
dc.description.abstractFollowing the success of forming a carbon S-phase (expanded austenite) surface layer on medical grade Ni-free austenitic stainless steel by DC plasma carburising, the established commercial carburising process Kolsterising® was performed on both Ni-containing (AISI 304) and Ni-free austenitic stainless steels. While the Ni-containing stainless steel responded very well to Kolsterising®, the Ni-free alloy did not. The carbon absorption and the hardness of the Kolsterised® Ni-free alloy are inferior to Kolsterised® AISI 304 Ni-containing stainless steel, however, the hardness of the untreated Ni-free alloy was doubled by Kolsterising®. The response of both Kolsterised® Ni-free and Ni-containing alloys to pitting, crevice corrosion and intergranular corrosion resistance was similar. From this work it can be concluded that the Kolsterised® austenitic stainless steels do not suffer from intergranular corrosion but are susceptible to intragranular pitting when tested in boiling sulphuric acid and copper sulphate solution. It was also observed that Kolsterising® improves significantly the pitting and crevice corrosion resistance of the alloys used in this study.en_GB
dc.language.isoenen_GB
dc.publisherElsevieren_GB
dc.rightsinfo:eu-repo/semantics/restrictedAccessen_GB
dc.subjectCorrosion and anti-corrosivesen_GB
dc.subjectAustenitic stainless steelen_GB
dc.subjectImplants, Artificialen_GB
dc.titleCorrosion behaviour of carbon S-phase created on Ni-free biomedical stainless steelen_GB
dc.typearticleen_GB
dc.rights.holderThe copyright of this work belongs to the author(s)/publisher. The rights of this work are as defined by the appropriate Copyright Legislation or as modified by any successive legislation. Users may access this work and can make use of the information contained in accordance with the Copyright Legislation provided that the author must be properly acknowledged. Further distribution or reproduction in any format is prohibited without the prior permission of the copyright holder.en_GB
dc.description.reviewedpeer-revieweden_GB
dc.identifier.doi10.1016/j.surfcoat.2012.02.020-
Appears in Collections:Scholarly Works - FacEngMME
Scholarly Works - FacSciChe

Files in This Item:
File Description SizeFormat 
OA - Corrosion behaviour of carbon S-phase created on Ni-free biomedical stainless steel.1.pdf
  Restricted Access
Corrosion behaviour of carbon S-phase created on Ni-free biomedical stainless steel1.95 MBAdobe PDFView/Open Request a copy


Items in OAR@UM are protected by copyright, with all rights reserved, unless otherwise indicated.