Please use this identifier to cite or link to this item:
https://www.um.edu.mt/library/oar/handle/123456789/18328
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Formosa, Dennis | - |
dc.contributor.author | Hunger, Ralph | - |
dc.contributor.author | Spiteri, Andre | - |
dc.contributor.author | Dong, Hanshan | - |
dc.contributor.author | Sinagra, Emmanuel | - |
dc.contributor.author | Buhagiar, Joseph P. | - |
dc.date.accessioned | 2017-04-15T19:56:29Z | - |
dc.date.available | 2017-04-15T19:56:29Z | - |
dc.date.issued | 2012 | - |
dc.identifier.citation | Formosa, D., Hunger, R., Spiteri, A., Dong, H., Sinagra, E., & Buhagiar, J. (2012). Corrosion behaviour of carbon S-phase created on Ni-free biomedical stainless steel. Surface and Coatings Technology, 206(16), 3479-3487. | en_GB |
dc.identifier.uri | https://www.um.edu.mt/library/oar//handle/123456789/18328 | - |
dc.description.abstract | Following the success of forming a carbon S-phase (expanded austenite) surface layer on medical grade Ni-free austenitic stainless steel by DC plasma carburising, the established commercial carburising process Kolsterising® was performed on both Ni-containing (AISI 304) and Ni-free austenitic stainless steels. While the Ni-containing stainless steel responded very well to Kolsterising®, the Ni-free alloy did not. The carbon absorption and the hardness of the Kolsterised® Ni-free alloy are inferior to Kolsterised® AISI 304 Ni-containing stainless steel, however, the hardness of the untreated Ni-free alloy was doubled by Kolsterising®. The response of both Kolsterised® Ni-free and Ni-containing alloys to pitting, crevice corrosion and intergranular corrosion resistance was similar. From this work it can be concluded that the Kolsterised® austenitic stainless steels do not suffer from intergranular corrosion but are susceptible to intragranular pitting when tested in boiling sulphuric acid and copper sulphate solution. It was also observed that Kolsterising® improves significantly the pitting and crevice corrosion resistance of the alloys used in this study. | en_GB |
dc.language.iso | en | en_GB |
dc.publisher | Elsevier | en_GB |
dc.rights | info:eu-repo/semantics/restrictedAccess | en_GB |
dc.subject | Corrosion and anti-corrosives | en_GB |
dc.subject | Austenitic stainless steel | en_GB |
dc.subject | Implants, Artificial | en_GB |
dc.title | Corrosion behaviour of carbon S-phase created on Ni-free biomedical stainless steel | en_GB |
dc.type | article | en_GB |
dc.rights.holder | The copyright of this work belongs to the author(s)/publisher. The rights of this work are as defined by the appropriate Copyright Legislation or as modified by any successive legislation. Users may access this work and can make use of the information contained in accordance with the Copyright Legislation provided that the author must be properly acknowledged. Further distribution or reproduction in any format is prohibited without the prior permission of the copyright holder. | en_GB |
dc.description.reviewed | peer-reviewed | en_GB |
dc.identifier.doi | 10.1016/j.surfcoat.2012.02.020 | - |
Appears in Collections: | Scholarly Works - FacEngMME Scholarly Works - FacSciChe |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
OA - Corrosion behaviour of carbon S-phase created on Ni-free biomedical stainless steel.1.pdf Restricted Access | Corrosion behaviour of carbon S-phase created on Ni-free biomedical stainless steel | 1.95 MB | Adobe PDF | View/Open Request a copy |