dc.date.issued2015-
dc.identifier.citationBottarelli, M., Bortoloni, M., Su, Y., Yousif, C., Aydın, A. A., & Georgiev, A. (2015). Numerical analysis of a novel ground heat exchanger coupled with phase change materials. Applied Thermal Engineering, 88, 369-375.en_GB
dc.identifier.urihttps://www.um.edu.mt/library/oar//handle/123456789/25533-
dc.description.abstractThermal energy storage with phase change materials (PCMs) is a functional strategy to minimize the sizing of air conditioning systems and reduce their primary energy consumption. This approach is well known in ground-coupled heat pump applications (GCHP), especially with use of borehole ground heat exchangers (GHEs). However, this is seldom investigated for coupling with shallow horizontal GHEs that are usually considered to be less effective for GCHP applications, due to faster depletion of the stored thermal energy as a result of the seasonal energy balance. In order to make shallow GHEs more effective, mixing PCMs directly with backfill material for a flat-panel type GHE is presented in this study. The application has been evaluated through numerical modelling to solve transient heat transfer using effective heat capacity method. Yearly performance has been simulated by taking into account the estimated energy requirement for an assumed residential building located in Northern Italy. According to hourly time series boundary conditions and annual performance, the simulation results show that employment of PCMs is able to smooth the thermal wave in the ground, improve the coefficient of performance of the heat pump (COP) and if suitably sized, prevent thermal depletion in winter by charging the PCMs naturally in summer with a shallow GHE.en_GB
dc.language.isoenen_GB
dc.publisherElsevier Ltd.en_GB
dc.rightsinfo:eu-repo/semantics/restrictedAccessen_GB
dc.subjectHeat storageen_GB
dc.subjectGround source heat pump systemsen_GB
dc.subjectHeat pumps -- Design and constructionen_GB
dc.subjectEnergy storageen_GB
dc.titleNumerical analysis of a novel ground heat exchanger coupled with phase change materialsen_GB
dc.typearticleen_GB
dc.rights.holderThe copyright of this work belongs to the author(s)/publisher. The rights of this work are as defined by the appropriate Copyright Legislation or as modified by any successive legislation. Users may access this work and can make use of the information contained in accordance with the Copyright Legislation provided that the author must be properly acknowledged. Further distribution or reproduction in any format is prohibited without the prior permission of the copyright holder.en_GB
dc.description.reviewedpeer-revieweden_GB
dc.identifier.doi10.1016/j.applthermaleng.2014.10.016-
dc.publication.titleApplied Thermal Engineeringen_GB
Appears in Collections:Scholarly Works - InsSE