Please use this identifier to cite or link to this item: https://www.um.edu.mt/library/oar/handle/123456789/26637
Full metadata record
DC FieldValueLanguage
dc.contributor.authorCasha, Aaron-
dc.contributor.authorYang, Lang-
dc.contributor.authorKay, Philip H.-
dc.contributor.authorSaleh, Michael-
dc.contributor.authorCooper, Graham J.-
dc.date.accessioned2018-02-09T08:29:03Z-
dc.date.available2018-02-09T08:29:03Z-
dc.date.issued1999-
dc.identifier.citationCasha, A. R., Yang, L., Kay, P. H., Saleh, M., & Cooper, G. J. (1999). A biomechanical study of median sternotomy closure techniques. European Journal of Cardio-Thoracic Surgery, 15(3), 365-369.en_GB
dc.identifier.urihttps://www.um.edu.mt/library/oar//handle/123456789/26637-
dc.description.abstractObjective: Sternal dehiscence is a complication of median sternotomy incisions with high mortality and morbidity. Different techniques of sternal closure have been described. Rigid fixation of the sternum results in earlier union. We measured the rigidity of sternotomy fixation using a mechanical model in order to differentiate different techniques of sternal closure using their biomechanical characteristics. Methods: We measured the force-displacement curves of six different fixation techniques using a metal sternal model using a computerized materials-testing machine. We tested straight wires (the most commonly used surgical technique), figure-of-8 wires, ‘repair’ technique (used when a wire breaks), Ethibond, Sterna-band and a ‘multitwist’ closure described for the first time. Results: At 20 kg force, twisted wires used for sternotomy closures start to untwist. The most rigid closure was a multitwist closure that displaced only 0.37 mm at a force of 20 kg. Straight wires displaced 0.78 mm, figure-of-8 wires 1.20 mm, Sterna-band 1.37 mm, repair wires 5.08 mm, Ethibond 9.37 mm. The single factor Anova test for the rigidity of the different closures had P-values <0.0001. Conclusions: We applied a mathematical model to calculate chest wall forces during coughing, in order to determine the force placed upon a sternotomy closure. We conclude that severe coughing may cause wires to untwist. We discuss potential applications of different wire closures based on their characteristics.en_GB
dc.language.isoenen_GB
dc.publisherOxford University Pressen_GB
dc.rightsinfo:eu-repo/semantics/restrictedAccessen_GB
dc.subjectBiomechanicsen_GB
dc.subjectSternotomyen_GB
dc.subjectSternum -- Surgeryen_GB
dc.titleA biomechanical study of median sternotomy closure techniquesen_GB
dc.typearticleen_GB
dc.rights.holderThe copyright of this work belongs to the author(s)/publisher. The rights of this work are as defined by the appropriate Copyright Legislation or as modified by any successive legislation. Users may access this work and can make use of the information contained in accordance with the Copyright Legislation provided that the author must be properly acknowledged. Further distribution or reproduction in any format is prohibited without the prior permission of the copyright holder.en_GB
dc.description.reviewedpeer-revieweden_GB
dc.identifier.doi10.1016/S1010-7940(99)00014-7-
dc.publication.titleEuropean Journal of Cardio-Thoracic Surgeryen_GB
Appears in Collections:Scholarly Works - FacM&SAna

Files in This Item:
File Description SizeFormat 
A_biomechanical_study_of_median_sternotomy_closure_techniques_1999.pdf
  Restricted Access
477.67 kBAdobe PDFView/Open Request a copy


Items in OAR@UM are protected by copyright, with all rights reserved, unless otherwise indicated.