Please use this identifier to cite or link to this item:
https://www.um.edu.mt/library/oar/handle/123456789/33443
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Casha, Aaron | - |
dc.contributor.author | Gatt, Ruben | - |
dc.contributor.author | Gauci, Marilyn | - |
dc.contributor.author | Vella, H. | - |
dc.contributor.author | Busuttil, K. | - |
dc.contributor.author | Grima, Joseph N. | - |
dc.date.accessioned | 2018-09-05T09:23:32Z | - |
dc.date.available | 2018-09-05T09:23:32Z | - |
dc.date.issued | 2011 | - |
dc.identifier.citation | Casha, A., Gatt, R., Gauci, M., Vella, H., Busuttil, K., & Grima, J. N. (2011). On stent design and Poisson’s ratios. 8 th International Workshop on Auxetics and Related Systems AUXETICS’11, Szczecin. 66. | en_GB |
dc.identifier.isbn | 9788393054947 | - |
dc.identifier.uri | https://www.um.edu.mt/library/oar//handle/123456789/33443 | - |
dc.description.abstract | Stents are artificial tubes which are inserted into natural passages in the body such as coronary vessels to prevent or counteract localized flow constriction. Here we discuss the characteristics of some of the more commonly used stents from a geometry-deformation mechanism point of view and show how our knowledge on the design of systems with tailor-made Poisson’s ratio can be used to design superior stents. | en_GB |
dc.language.iso | en | en_GB |
dc.publisher | Task Publishing | en_GB |
dc.rights | info:eu-repo/semantics/restrictedAccess | en_GB |
dc.subject | Stents (Surgery) | en_GB |
dc.subject | Surgical instruments and apparatus | en_GB |
dc.subject | Biomechanics | en_GB |
dc.title | On stent design and Poisson’s ratios | en_GB |
dc.type | conferenceObject | en_GB |
dc.rights.holder | The copyright of this work belongs to the author(s)/publisher. The rights of this work are as defined by the appropriate Copyright Legislation or as modified by any successive legislation. Users may access this work and can make use of the information contained in accordance with the Copyright Legislation provided that the author must be properly acknowledged. Further distribution or reproduction in any format is prohibited without the prior permission of the copyright holder | en_GB |
dc.bibliographicCitation.conferencename | 8 th International Workshop on Auxetics and Related Systems AUXETICS’11 | en_GB |
dc.bibliographicCitation.conferenceplace | Szczecin, Poland, 06–09/09/2011 | en_GB |
dc.description.reviewed | peer-reviewed | en_GB |
Appears in Collections: | Scholarly Works - FacM&SAna |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
On_stent_design_and_Poissons_ratios.pdf Restricted Access | 50.33 kB | Adobe PDF | View/Open Request a copy |
Items in OAR@UM are protected by copyright, with all rights reserved, unless otherwise indicated.