dc.identifier.citationPace I.M. (2012). Sequential CT vs. spiral CT brain imaging (Bachelor's dissertation).en_GB
dc.identifier.urihttps://www.um.edu.mt/library/oar/handle/123456789/53487-
dc.descriptionB.SC.(HONS)RADIOGRAPHYen_GB
dc.description.abstractPurpose: The purpose of this study was to evaluate and compare sequential CT to spiral CT examinations for the brain, performed on a GE Highspeed Dual NX/1 Plus 2 slice with regards to image quality and radiation dose at the local general hospital. Methodology: The study was carried out prospectively on 40 patients referred for a brain CT examination. An equal number of patients were gathered for each scanning protocol; either sequential (n=20) or spiral (n=20). A checklist was filled in during every CT brain exam to collect radiation dose parameter data in terms of CTDIvol and DLP. Another checklist was given to four radiologists to visually grade the quality of the CT images using the European image quality criteria for CT. Results: Mean CTDIvol and DLP readings were significantly higher (p \<0.05) for the sequential technique than the spiral technique (CTDIvol: 22.06mGy versus 14.94mGy and DLP: 304.60mGycm versus 229.10mGycm). The sequential technique was graded higher in image quality as all the mean grading scores were significantly (p \< 0.05) higher than those obtained by the spiral technique. Conclusions: Spiral acquired CT images of the brain have a lower radiation dose but have an overall lower image quality compared to the images obtained using the sequential technique. However, further research is recommended investigating the diagnostic efficacy of the image quality of spiral technique is good enough for diagnosis.en_GB
dc.language.isoenen_GB
dc.rightsinfo:eu-repo/semantics/restrictedAccessen_GB
dc.subjectBrain -- Imagingen_GB
dc.subjectTomographyen_GB
dc.subjectImaging systems -- Image qualityen_GB
dc.subjectRadiation dosimetryen_GB
dc.subjectSpiral computed tomographyen_GB
dc.titleSequential CT vs. spiral CT brain imaging.en_GB
dc.typebachelorThesisen_GB
dc.rights.holderThe copyright of this work belongs to the author(s)/publisher. The rights of this work are as defined by the appropriate Copyright Legislation or as modified by any successive legislation. Users may access this work and can make use of the information contained in accordance with the Copyright Legislation provided that the author must be properly acknowledged. Further distribution or reproduction in any format is prohibited without the prior permission of the copyright holderen_GB
dc.publisher.institutionUniversity of Maltaen_GB
dc.publisher.departmentFaculty of Health Sciences. Department of Radiographyen_GB
dc.contributor.supervisorZarb, Francis-
dc.description.reviewedN/Aen_GB
dc.contributor.creatorPace, Ivana Maria-
Appears in Collections:Dissertations - FacHSc - 2012
Dissertations - FacHScRad - 2012

Files in This Item:
File Description SizeFormat 
Pace_Ivana_Maria_SEQUENTIAL CT VS. SPIRAL CT BRAIN IMAGING.pdf
  Restricted Access
3.42 MBAdobe PDFView/Open Request a copy


Items in OAR@UM are protected by copyright, with all rights reserved, unless otherwise indicated.