Please use this identifier to cite or link to this item: https://www.um.edu.mt/library/oar/handle/123456789/88775
Title: MITEoR : a scalable interferometer for precision 21 cm cosmology
Authors: Zheng, H.
Tegmark, M.
Buza, V.
Dillon, J. S.
Gharibyan, H.
Hickish, J.
Kunz, E.
Liu, A.
Losh, J.
Lutomirski, A.
Morrison, S.
Narayanan, S.
Perko, A.
Rosner, D.
Sanchez, N
Schutz, K.
Tribiano, S. M.
Valdez, M.
Yang, H.
Zarb Adami, Kristian
Zelko, I.
Zheng, K.
Armstrong, R. P.
Bradley, R. F.
Dexter, M. R.
Ewall-Wice, A.
Magro, Alessio
Matejek, M.
Morgan, E.
Neben, A. R.
Pan, Q.
Penna, R. F.
Peterson, C. M.
Su, M
Villasenor, J.
Williams, C. L.
Zhu, Y.
Keywords: Radio interferometers -- Calibration
Radio astronomy
Cosmology
Antenna arrays -- Calibration
Issue Date: 2014
Publisher: Oxford University Press
Citation: Zheng, H., Tegmark, M., Buza, V., Dillon, J. S., Gharibyan, H., Hickish, J.,...Zhu, Y. (2014). MITEoR: a scalable interferometer for precision 21 cm cosmology. Monthly Notices of the Royal Astronomical Society, 445(2), 1084-1103.
Abstract: We report on the MIT Epoch of Reionization (MITEoR) experiment, a pathfinder lowfrequency radio interferometer whose goal is to test technologies that improve the calibration precision and reduce the cost of the high-sensitivity 3D mapping required for 21 cm cosmology. MITEoR accomplishes this by using massive baseline redundancy, which enables both automated precision calibration and correlator cost reduction. We demonstrate and quantify the power and robustness of redundancy for scalability and precision. We find that the calibration parameters precisely describe the effect of the instrument upon our measurements, allowing us to form a model that is consistent with χ2 per degree of freedom <1.2 for as much as 80 per cent of the observations. We use these results to develop an optimal estimator of calibration parameters using Wiener filtering, and explore the question of how often and how finely in frequency visibilities must be reliably measured to solve for calibration coefficients. The success of MITEoR with its 64 dual-polarization elements bodes well for the more ambitious Hydrogen Epoch of Reionization Array project and other next-generation instruments, which would incorporate many identical or similar technologies.
URI: https://www.um.edu.mt/library/oar/handle/123456789/88775
Appears in Collections:Scholarly Works - InsSSA

Files in This Item:
File Description SizeFormat 
MITEoR_a_scalable_interferometer_for_precision_21_cm_cosmology_2014.pdf
  Restricted Access
8.51 MBAdobe PDFView/Open Request a copy


Items in OAR@UM are protected by copyright, with all rights reserved, unless otherwise indicated.