Please use this identifier to cite or link to this item: https://www.um.edu.mt/library/oar/handle/123456789/93227
Full metadata record
DC FieldValueLanguage
dc.contributor.authorClevert, D. A.-
dc.contributor.authorHelck, A.-
dc.contributor.authorD'Anastasi, Melvin-
dc.contributor.authorGurtler, V.-
dc.contributor.authorSommer, W. H.-
dc.contributor.authorMeimarakis, G.-
dc.contributor.authorWeidenhagen, R.-
dc.contributor.authorReiser, M.-
dc.date.accessioned2022-04-08T13:04:49Z-
dc.date.available2022-04-08T13:04:49Z-
dc.date.issued2011-
dc.identifier.citationClevert, D. A., Helck, A., D'Anastasi, M., Gürtler, V., Sommer, W. H., Meimarakis, G.,...Reiser, M. (2011). Improving the follow up after EVAR by using ultrasound image fusion of CEUS and MS-CT. Clinical Hemorheology and Microcirculation, 49(1-4), 91-104.en_GB
dc.identifier.urihttps://www.um.edu.mt/library/oar/handle/123456789/93227-
dc.description.abstractPurpose: To evaluate whether the image fusion with contrast enhanced ultrasound (CEUS) and CT affects the diagnosis of endoleaks in unclear cases.en_GB
dc.description.abstractMethods and materials: 35 patients with follow-up examinations after enodvascular aneurysm repair (EVAR) were included in this retrospective study. Mean patient age was 73 years (range 54–83 y). B-scan, colour doppler and CEUS (1.2 ml SonoVue®, Bracco Imaging Germany) were performed in all patients by an experienced examiner using two different high-end ultrasound system (Siemens ACUSON S2000™, Siemens Healthcare, Erlangen, Germany or Logic E9, GE Healthcare, Milwaukee,WI, USA) with a multifrequency curved array transducer. The examiner was initially blinded to the CT results. Additional image fusion with CT-angiography (CTA) was then performed. The ultrasound examinations were later read by two blinded unbiased investigators with more than five years of clinical ultrasound in consensus.en_GB
dc.description.abstractResults: All patients were examined using all diagnostic ultrasound tools of the study. The results show that image fusion is easy and convenient to perform. Conventional ultrasound examination with B-scan and colour Doppler examination detected one Type I and one Type II endoleak, contrast enhanced ultrasound detected one Type I and three Type II endoleaks after EVAR whereas CTA depicted one Type I and two Type II endoleaks. Ultrasound image fusion with CT-angiography confirmed one Type I and three Type II endoleaks.en_GB
dc.description.abstractConclusion: In comparison to conventional ultrasound and CTA the use of CEUS improved the visualization and classification of endoleaks. CEUS shows even small blood flow which can be depicted due to the real time imaging of endoleaks. In unclear cases additional ultrasound image fusion with CEUS and CT angiography improves the visualisation of small endoleaks and this may cause a change in the follow-up interval. CEUS is a good alternative to CT in the detection and follow-up of endoleaks, especially in patients with contraindications to CT contrast agents due to allergies or renal failure, enabling reduced additional costs and exposure to radiation.en_GB
dc.language.isoenen_GB
dc.publisherIOS Pressen_GB
dc.rightsinfo:eu-repo/semantics/restrictedAccessen_GB
dc.subjectDiagnostic ultrasonic imaging -- Equipment and suppliesen_GB
dc.subjectContrast-enhanced ultrasounden_GB
dc.subjectAortic aneurysmsen_GB
dc.subjectHeart -- Ultrasonic imagingen_GB
dc.subjectAngiography -- Methodsen_GB
dc.subjectUltrasound contrast mediaen_GB
dc.titleImproving the follow up after EVAR by using ultrasound image fusion of CEUS and MS-CTen_GB
dc.typearticleen_GB
dc.rights.holderThe copyright of this work belongs to the author(s)/publisher. The rights of this work are as defined by the appropriate Copyright Legislation or as modified by any successive legislation. Users may access this work and can make use of the information contained in accordance with the Copyright Legislation provided that the author must be properly acknowledged. Further distribution or reproduction in any format is prohibited without the prior permission of the copyright holder.en_GB
dc.description.reviewedpeer-revieweden_GB
dc.identifier.doi10.3233/CH-2011-1460-
dc.publication.titleClinical Hemorheology and Microcirculationen_GB
Appears in Collections:Scholarly Works - FacM&SCRNM

Files in This Item:
File Description SizeFormat 
Improving_the_follow_up_after_EVAR_by_using_ultrasound_image_fusion_of_CEUS_and_MS_CT_2011.pdf
  Restricted Access
1.77 MBAdobe PDFView/Open Request a copy


Items in OAR@UM are protected by copyright, with all rights reserved, unless otherwise indicated.