dc.contributor.author | Zarb, Francis | - |
dc.contributor.author | McEntee, Mark | - |
dc.contributor.author | Rainford, Louise | - |
dc.date.accessioned | 2023-02-24T15:08:19Z | - |
dc.date.available | 2023-02-24T15:08:19Z | - |
dc.date.issued | 2012 | - |
dc.identifier.citation | Zarb, F., McEntee, M., & Rainford, L. (2012). Maltese CT doses for commonly performed examinations demonstrate alignment with published DRLs across Europe. Radiation protection dosimetry, 150(2), 198-206. | en_GB |
dc.identifier.uri | https://www.um.edu.mt/library/oar/handle/123456789/106827 | - |
dc.description.abstract | This work recommends dose reference levels (DRLs) for abdomen, chest and head computerised tomography (CT) examinations in Malta as the first step towards national CT dose optimisation. Third quartiles volume CT dose index values for abdomen: 12.1 mGy, chest: 13.1 mGy and head: 41 mGy and third quartile dose-length product values for abdomen: 539.4, chest: 492 and head: 736 mGy cm–1 are recommended as Maltese DRLs derived from this first Maltese CT dose survey. These values compare well with DRLs of other European countries indicating that CT scanning in Malta is consistent with standards of good practice. Further work to minimise dose without affecting image quality and extending the establishment of DRLs for other CT examinations is recommended. | en_GB |
dc.language.iso | en | en_GB |
dc.publisher | Oxford University Press | en_GB |
dc.rights | info:eu-repo/semantics/restrictedAccess | en_GB |
dc.subject | Abdomen -- Anatomy | en_GB |
dc.subject | Radiation -- Dosage -- Standards | en_GB |
dc.subject | Radiation -- Health aspects | en_GB |
dc.subject | Radiography, Medical -- Image quality | en_GB |
dc.subject | Chest -- Radiography | en_GB |
dc.subject | X-rays -- Safety measures | en_GB |
dc.subject | X-rays -- Equipment and supplies | en_GB |
dc.subject | Radiography, Medical -- Equipment and supplies | en_GB |
dc.title | Maltese CT doses for commonly performed examinations demonstrate alignment with published DRLs across Europe | en_GB |
dc.type | article | en_GB |
dc.rights.holder | The copyright of this work belongs to the author(s)/publisher. The rights of this work are as defined by the appropriate Copyright Legislation or as modified by any successive legislation. Users may access this work and can make use of the information contained in accordance with the Copyright Legislation provided that the author must be properly acknowledged. Further distribution or reproduction in any format is prohibited without the prior permission of the copyright holder | en_GB |
dc.description.reviewed | peer-reviewed | en_GB |
dc.identifier.doi | 10.1093/rpd/ncr393 | - |
dc.publication.title | Radiation protection dosimetry | en_GB |