Please use this identifier to cite or link to this item: https://www.um.edu.mt/library/oar/handle/123456789/86321
Full metadata record
DC FieldValueLanguage
dc.contributor.authorWang, Yong C.-
dc.contributor.authorWald, Frantisek-
dc.date.accessioned2022-01-04T10:44:18Z-
dc.date.available2022-01-04T10:44:18Z-
dc.date.issued2008-
dc.identifier.citationWang, Y. C., & Wald, F. (2008). Heat transfer analysis. In Mazzolani, F. M., Mistakidis, E., Borg, R. P., Byfield, M., De Matteis, G., Dubina.,..Wang, Y. (Eds.), Urban habitat constructions under catastrophic events: COST Action C26 (pp. 22-27). Malta: University of Malta. Dept. of Building & Civil Engineering.en_GB
dc.identifier.isbn9789990944402-
dc.identifier.urihttps://www.um.edu.mt/library/oar/handle/123456789/86321-
dc.description.abstract▪ Prediction of fire resistance of a structure follows three general steps: evaluation of fire exposure condition (fire dynamics), calculation of structural temperatures under fire exposure (heat transfer analysis), determination of structural resistance at elevated temperatures (structural analysis). Heat transfer analysis links fire dynamics with structural analysis.en_GB
dc.description.abstract▪ Structural temperatures may be obtained by many means, including fire tests, look up tables or graphs or calculations. Look up tables or graphs are based on limited fire tests or calculations. Their application ranges are limited. This technical sheet gives information on heat transfer analysis by calculations.en_GB
dc.language.isoenen_GB
dc.publisherUniversity of Malta. Department of Building & Civil Engineeringen_GB
dc.rightsinfo:eu-repo/semantics/restrictedAccessen_GB
dc.subjectHeat -- Transmission -- Mathematical modelsen_GB
dc.subjectFire -- Mathematical modelsen_GB
dc.subjectStructural analysis (Engineering)en_GB
dc.subjectFire protection engineeringen_GB
dc.subjectMaterials -- Thermal propertiesen_GB
dc.titleHeat transfer analysisen_GB
dc.typebookParten_GB
dc.rights.holderThe copyright of this work belongs to the author(s)/publisher. The rights of this work are as defined by the appropriate Copyright Legislation or as modified by any successive legislation. Users may access this work and can make use of the information contained in accordance with the Copyright Legislation provided that the author must be properly acknowledged. Further distribution or reproduction in any format is prohibited without the prior permission of the copyright holder.en_GB
dc.description.reviewedpeer-revieweden_GB
Appears in Collections:Urban habitat constructions under catastrophic events : COST Action C26