Please use this identifier to cite or link to this item: https://www.um.edu.mt/library/oar/handle/123456789/26983
Title: Beam feasibility study of a collimator with in-jaw beam position monitors
Authors: Wollmann, Daniel
Nosych, Andriy A.
Valentino, Gianluca
Aberle, Oliver
Assmann, Ralph W.
Bertarelli, Alessandro
Boccard, Christian
Bruce, Roderik
Burkart, Florian
Calvo, Eva
Demicoli, Marija
Dallocchio, Alessandro
Deboy, Daniel
Gasior, Marek
Jones, Rhodri
Kain, Verena
Lari, Luisella
Redaelli, Stefano
Rossi, Adriana
Keywords: Colliders (Nuclear physics)
Nuclear physics
Large Hadron Collider (France and Switzerland)
Issue Date: 2014
Publisher: Elsevier
Citation: Wollmann, D., Nosych, A. A., Valentino, G., Aberle, O., Aßmann, R. W., Bertarelli, A.,... Rossi, A. (2014). Beam feasibility study of a collimator with in-jaw beam position monitors. Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 768, 62-68.
Abstract: At present, the beam-based alignment of the LHC collimators is performed by touching the beam halo with both jaws of each collimator. This method requires dedicated fills at low intensities that are done infrequently and makes this procedure time consuming. This limits the operational flexibility, in particular in the case of changes of optics and orbit configuration in the experimental regions. The performance of the LHC collimation system relies on the machine reproducibility and regular loss maps to validate the settings of the collimator jaws. To overcome these limitations and to allow a continuous monitoring of the beam position at the collimators, a design with jaw-integrated Beam Position Monitors (BPMs) was proposed and successfully tested with a prototype (mock-up) collimator in the CERN SPS. Extensive beam experiments allowed to determine the achievable accuracy of the jaw alignment for single and multi-turn operation. In this paper, the results of these experiments are discussed. The non-linear response of the BPMs is compared to the predictions from electromagnetic simulations. Finally, the measured alignment accuracy is compared to the one achieved with the present collimators in the LHC.
URI: https://www.um.edu.mt/library/oar//handle/123456789/26983
Appears in Collections:Scholarly Works - FacICTCCE
Scholarly Works - InsSE

Files in This Item:
File Description SizeFormat 
Beam_feasibility_study_of_a_collimator_within_jaw_2014.pdf1.84 MBAdobe PDFView/Open


Items in OAR@UM are protected by copyright, with all rights reserved, unless otherwise indicated.