Title: Transcatheter closure of symptomatic aortopulmonary window in an infant
Authors: Pillekamp, Frank
Hannes, Tobias
Koch, Daniel
Brockmeier, Konrad
Sreeram, Narayanswami
Keywords: Cardiac catheterization
Congenital heart disease
Blood vessel prosthesis implantation
Issue Date: 2008
Publisher: Images in Paediatric Cardiology
Citation: Images in Paediatric Cardiology. 2008, Vol.10(2), p. 11-17
Abstract: An aortopulmonary window is a rare congenital cardiac defect. In the majority of symptomatic neonates and infants, primary surgical repair is the treatment of choice. In selected infants, catheter closure of the defect with a device may be feasible. This article reports on the successful closure of an AP window in a 12 month old infant, using a 6mm Amplatzer septal occluder. The procedure and follow-up were uneventful.