Please use this identifier to cite or link to this item: https://www.um.edu.mt/library/oar/handle/123456789/150988
Title: Comparison of microbroth dilution with phoenix automated system and minimum inhibitory concentration (MIC) strips for meropenem sensitivity testing for carbapenem resistant enterobacterales (CRE)
Authors: Camilleri, Miguel (2026)
Keywords: Drug resistance in microorganisms
Enterobacteriaceae
Microbial sensitivity tests
Issue Date: 2026
Citation: Camilleri, M. (2026). Comparison of microbroth dilution with phoenix automated system and minimum inhibitory concentration (MIC) strips for meropenem sensitivity testing for carbapenem resistant enterobacterales (CRE) (Bachelor's dissertation).
Abstract: Antibiotic resistance is a growing concern leading to the emergence of multidrug resistant bacterial strains that are difficult to treat. One such group comprises the carbapenem resistant Enterobacterales (CREs) which are resistant to the carbapenems such as Meropenem. Since Meropenem is used in high doses to treat CRE infections, susceptibility testing of this antibiotic is routinely conducted at Mater Dei Hospital. The broth microdilution (BMD) method is regarded as the gold standard method to carry out such tests, however, other systems more suited for diagnostic laboratories are employed at the hospital, namely BD Phoenix M50TM and minimum inhibitory concentration (MIC) strips. The ability to obtain reliable and accurate results from these systems is yet to be established and was thus the aim of this study. Their efficacy was assessed by performing Meropenem BMD on a total of 221 stored bacterial isolates. The BMD MIC results for these organisms were then compared to retrospective results obtained from the systems employed at Mater Dei Hospital for these same organisms to determine their comparability. Statistical analysis showed high categorical agreement for BD Phoenix M50™ (94.57%) and MIC strips (92.31%) with BMD, with substantial agreement (κ = 0.830 and 0.739; p < 0.001), although essential agreement was low (60.63% and 28.96%) and very major error rates were elevated (15.56% and 31.1%) respectively. In conclusion, despite the presence of notable error rates, sufficient agreement in susceptibility categorisation supports the continued use of these systems in routine diagnostics, with BMD recommended as a confirmatory method in cases of discrepant results rather than as a primary testing method.
Description: B.Sc. (Hons)(Melit.)
URI: https://www.um.edu.mt/library/oar/handle/123456789/150988
Appears in Collections:Dissertations - FacHSc - 2026
Dissertations - FacHScABS - 2026

Files in This Item:
File Description SizeFormat 
2608HSCMLS420000017834_1.PDF
  Restricted Access
1.62 MBAdobe PDFView/Open Request a copy


Items in OAR@UM are protected by copyright, with all rights reserved, unless otherwise indicated.