Please use this identifier to cite or link to this item: https://www.um.edu.mt/library/oar/handle/123456789/89289
Title: Analytical, numerical and experimental study of a horizontal electrothermal MEMS microgripper for the deformability characterisation of human red blood cells
Authors: Demicoli, Marija
Grech, Ivan
Mallia, Bertram
Mollicone, Pierluigi
Sammut, Nicholas
Keywords: Microelectromechanical systems
Erythrocytes
Furnace atomic absorption spectroscopy
Finite element method
Temperature
Strains and stresses
Issue Date: 2018
Publisher: MDPI
Citation: Cauchi, M., Grech, I., Mallia, B., Mollicone, P., & Sammut, N. (2018). Analytical, numerical and experimental study of a horizontal electrothermal MEMS microgripper for the deformability characterisation of human red blood cells. Micromachines, 9(3), 108.
Abstract: Microgrippers are typical microelectromechanical systems (MEMS) that are widely used for micromanipulation and microassembly in both biological and micromanufacturing fields. This paper presents the design, modelling, fabrication and experimental testing of an electrothermal microgripper based on a ‘hot and cold arm’ actuator design that is suitable for the deformability characterisation of human red blood cells (RBCs). The analysis of the mechanical properties of human RBCs is of great interest in the field of medicine as pathological alterations in the deformability characteristics of RBCs have been linked to a number of diseases. The study of the microgripper’s steady-state performance is initially carried out by the development of a lumped analytical model, followed by a numerical model established in CoventorWare® (Coventor, Inc., Cary, NC, USA) using multiphysics finite element analysis. Both analytical and numerical models are based on an electothermomechanical analysis, and take into account the internal heat generation due to the applied potential, as well as conduction heat losses through both the anchor pads and the air gap to the substrate. The models are used to investigate key factors of the actuator’s performance including temperature distribution, deflection and stresses based on an elastic analysis of structures. Results show that analytical and numerical values for temperature and deflection are in good agreement. The analytical and computational models are then validated experimentally using a polysilicon microgripper fabricated by the standard surface micromachining process, PolyMUMPs™ (Durham, NC, USA). The microgripper’s actuation is characterised at atmospheric pressure by optical microscopy studies. Experimental results for the deflection of the microgripper arm tips are found to be in good agreement with the analytical and numerical results, with process-induced variations and the non-linear temperature dependence of the material properties accounting for the slight discrepancies observed. The microgripper is shown to actuate to a maximum opening displacement of 9 μ m at an applied voltage of 3 V, thus being in line with the design requirement of an approximate opening of 8 μ m for securing and characterising a RBC.
URI: https://www.um.edu.mt/library/oar/handle/123456789/89289
Appears in Collections:Scholarly Works - FacEngMME
Scholarly Works - InsSE



Items in OAR@UM are protected by copyright, with all rights reserved, unless otherwise indicated.