Title: Understanding 3D TSE sequences : advantages, disadvantages, and application in MSK imaging
Authors: Glaser, Christian
D'Anastasi, Melvin
Theisen, Daniel
Notohamiprodjo, Mike
Horger, Wilhelm
Paul, Dominik
Horng, Annie
Keywords: Three-dimensional imaging in medicine -- Technique
Imaging systems in medicine
Spinal cord -- Imaging
Musculoskeletal system -- Imaging
Echo-planar imaging
Issue Date: 2015
Publisher: Thieme Medical
Citation: Glaser, C., D'Anastasi, M., Theisen, D., Notohamiprodjo, M., Horger, W., Paul, D., & Horng, A. (2015). Understanding 3D TSE sequences: advantages, disadvantages, and application in MSK imaging. Seminars in Musculoskeletal Radiology, 19(4), 321-327.
Abstract: Three-dimensional (3D) turbo-spin echo (TSE) sequences have outgrown the stage of mere sequence optimization and by now are clinically applicable. Image blurring and acquisition times have been reduced, and contrast for T1-, T2-, and moderately T2- weighted (or intermediate-weighted) fat-suppressed variants has been optimized. Data on sound-to-noise ratio efficiency and contrast are available for moderately T2-weighted fat-saturated sequence protocols. The 3-T MRI scanners help to better exploit isotropic spatial resolution and multiplanar reformatting. Imaging times range from 5 to 10 minutes, and they are shorter than the cumulative acquisition times of three separate orthogonal two-dimensional (2D) sequences. Recent suggestions go beyond secondary reformations by using online 3D rendering for image evaluation. Comparative clinical studies indicate that the diagnostic performance of 3D TSE for imaging of internal derangements of joints is at least comparable with conventional 2D TSE with potential advantages of 3D TSE for small highly curved structures. But such studies, especially those with direct arthroscopic correlation, are still sparse. Whether 3D TSE will succeed in entering clinical routine imaging on a broader scale will depend on further published clinical evidence, on further reduction of imaging time, and on improvement of its integration into daily practice.
URI: https://www.um.edu.mt/library/oar/handle/123456789/94587
Appears in Collections:Scholarly Works - FacM&SCRNM

Files in This Item:
File Description SizeFormat 
Understanding_3D_TSE_sequences_advantages_disadvantages_and_application_in_MSK_imaging_2015.pdf
  Restricted Access
355.2 kBAdobe PDFView/Open Request a copy


Items in OAR@UM are protected by copyright, with all rights reserved, unless otherwise indicated.